This resource identifies an instance of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.
Name | Card. | Type | Description & Constraints |
---|---|---|---|
Device | Device | An instance of a manufactured item that is used in the provision of healthcare | |
identifier | 0..* | Identifier | Instance id from manufacturer, owner, and others |
value | 1..1 | String | System or medical device identifier Example Value DXH12345 |
assigner | 0..1 | Reference (careconnect-organization-1) | Organization that issued id (may be just text) |
reference | 0..1 | String | Relative URL reference |
display | 0..1 | String | Text alternative for the resource |
type | 1..1 | CodeableConcept | What kind of device this is Binding Defines the nature of the device and the kind of functionality/services/behavior that may be expected from it. (http://fhir.nhs.net/ValueSet/device-type-1) Binding Strength Preferred |
coding | 0..1 | Coding | SNOMED CT representation of the device type Binding A code from the SNOMED Clinical Terminology UK coding system that describes a type of device. (http://fhir.nhs.net/ValueSet/device-type-1) Binding Strength Preferred |
system | 1..1 | Uri | Identity of the terminology system Fixed Value http://snomed.info/sct |
code | 1..1 | Code | Symbol in syntax defined by the system |
display | 1..1 | String | Representation defined by the system |
userSelected | 0..1 | Boolean | If this coding was chosen directly by the user |
note | 0..* | Annotation | Device notes and comments |
author[x] | 0..1 | Reference (careconnect-practitioner-1 | cofe-related-person-1) | Individual responsible for the annotation |
time | 0..1 | DateTime | When the annotation was made |
text | 1..1 | String | The annotation - text content |
status | 0..1 | Code | available | not-available | entered-in-error Binding The availability status of the device. (http://hl7.org/fhir/ValueSet/devicestatus) Binding Strength Required |
manufacturer | 0..1 | String | Name of device manufacturer |
model | 0..1 | String | Model id assigned by the manufacturer Example Value AA 1001-C |
version | 0..1 | String | Version number (i.e. software) Example Value 8.15-04 |
manufactureDate | 0..1 | DateTime | Manufacture date |
expiry | 0..1 | DateTime | Date and time of expiry of this device (if applicable) |
lotNumber | 0..1 | String | Lot number of manufacture |
owner | 0..1 | Reference (careconnect-organization-1) | Organization responsible for device |
reference | 1..1 | String | Relative URL reference |
display | 0..1 | String | Narrative text for the resource |
location | 0..1 | Reference (cofe-location-1) | Where the resource is found |
reference | 1..1 | String | Relative, internal or absolute URL reference |
display | 0..1 | String | Text alternative for the resource |
patient | 0..1 | Reference (careconnect-patient-1) | If the resource is affixed to a person |
reference | 1..1 | String | Relative, internal or absolute URL reference |
display | 0..1 | String | Text alternative for the resource |
contact | 0..* | ContactPoint | Details for human/organization for support |
system | 1..1 | Code | phone | fax | email | pager | other Binding Telecommunications form for contact point (http://hl7.org/fhir/ValueSet/contact-point-system) Binding Strength Required Example Value phone |
value | 1..1 | String | The actual contact point details Example Value 0191 4021111 |
use | 0..1 | Code | home | work | temp | old | mobile - purpose of this contact point Binding Use of contact point (http://hl7.org/fhir/ValueSet/contact-point-use) Binding Strength Required Example Value work |
rank | 0..1 | PositiveInt | Specify preferred order of use (1 = highest) Example Value 1 |
period | 0..1 | Period | Time period when the contact point was/is in use |
start | 0..1 | DateTime | Starting time with inclusive boundary |
end | 0..1 | DateTime | End time with inclusive boundary, if not ongoing |
url | 0..1 | Uri | Network address to contact device |
Path | Name | Binding Strength | ValueSet |
---|---|---|---|
Device.type | type | Preferred | http://fhir.nhs.net/ValueSet/device-type-1 |
Device.type.coding | coding | Preferred | http://fhir.nhs.net/ValueSet/device-type-1 |
Device.contact.system | system | Required | http://hl7.org/fhir/ValueSet/contact-point-system |
Device.contact.use | use | Required | http://hl7.org/fhir/ValueSet/contact-point-use |