CDA On FHIR England - Document Header

COFE-Device-1

This resource identifies an instance of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.

NameCard.TypeDescription & Constraints
..DeviceDeviceAn instance of a manufactured item that is used in the provision of healthcare

...identifier0..*IdentifierInstance id from manufacturer, owner, and others

....value1..1StringSystem or medical device identifier
Example Value DXH12345

....assigner0..1Reference (careconnect-organization-1)Organization that issued id (may be just text)

.....reference0..1StringRelative URL reference

.....display0..1StringText alternative for the resource

...type1..1CodeableConceptWhat kind of device this is
Binding Defines the nature of the device and the kind of functionality/services/behavior that may be expected from it. (http://fhir.nhs.net/ValueSet/device-type-1)
Binding Strength Preferred

....coding0..1CodingSNOMED CT representation of the device type
Binding A code from the SNOMED Clinical Terminology UK coding system that describes a type of device. (http://fhir.nhs.net/ValueSet/device-type-1)
Binding Strength Preferred

.....system1..1UriIdentity of the terminology system
Fixed Value http://snomed.info/sct

.....code1..1CodeSymbol in syntax defined by the system

.....display1..1StringRepresentation defined by the system

.....userSelected0..1BooleanIf this coding was chosen directly by the user

...note0..*AnnotationDevice notes and comments

....author[x]0..1Reference (careconnect-practitioner-1 | cofe-related-person-1)Individual responsible for the annotation

....time0..1DateTimeWhen the annotation was made

....text1..1StringThe annotation - text content

...status0..1Codeavailable | not-available | entered-in-error
Binding The availability status of the device. (http://hl7.org/fhir/ValueSet/devicestatus)
Binding Strength Required

...manufacturer0..1StringName of device manufacturer

...model0..1StringModel id assigned by the manufacturer
Example Value AA 1001-C

...version0..1StringVersion number (i.e. software)
Example Value 8.15-04

...manufactureDate0..1DateTimeManufacture date

...expiry0..1DateTimeDate and time of expiry of this device (if applicable)

...lotNumber0..1StringLot number of manufacture

...owner0..1Reference (careconnect-organization-1)Organization responsible for device

....reference1..1StringRelative URL reference

....display0..1StringNarrative text for the resource

...location0..1Reference (cofe-location-1)Where the resource is found

....reference1..1StringRelative, internal or absolute URL reference

....display0..1StringText alternative for the resource

...patient0..1Reference (careconnect-patient-1)If the resource is affixed to a person

....reference1..1StringRelative, internal or absolute URL reference

....display0..1StringText alternative for the resource

...contact0..*ContactPointDetails for human/organization for support

....system1..1Codephone | fax | email | pager | other
Binding Telecommunications form for contact point (http://hl7.org/fhir/ValueSet/contact-point-system)
Binding Strength Required
Example Value phone

....value1..1StringThe actual contact point details
Example Value 0191 4021111

....use0..1Codehome | work | temp | old | mobile - purpose of this contact point
Binding Use of contact point (http://hl7.org/fhir/ValueSet/contact-point-use)
Binding Strength Required
Example Value work

....rank0..1PositiveIntSpecify preferred order of use (1 = highest)
Example Value 1

....period0..1PeriodTime period when the contact point was/is in use

.....start0..1DateTimeStarting time with inclusive boundary

.....end0..1DateTimeEnd time with inclusive boundary, if not ongoing

...url0..1UriNetwork address to contact device