MedicalDevices Tabular View
COCD_TP146054GB01 | |
SupplyMedicalDevice |
This template class constrains the CDA supply class. This template class is used to hold details of medical devices that do not appear in the dictionary of medicines and devices (dm+d) |
Used by: | |
[1..1] [M] classCode (CS { CNE: ActClass } ) { Fixed="SPLY" } |
Model Attribute Description The HL7 attribute classCode uses a code to describe this class as a supply. Implementation in XML Instance
|
[1..1] [M] moodCode (CS { CNE: ActMood } ) { Fixed="EVN" } |
Model Attribute Description The HL7 attribute moodCode uses a code to describe this class as a supply event. Implementation in XML Instance
|
[1..1] [M] code (CV { CNE:CDAObservationType } ) { Fixed="MDS" } |
Model Attribute Description Implementation in XML Instance The Coded Value (CV) data type shall be used to carry this information in the XML element code as follows:
|
[1..1] [M] id (II) |
Model Attribute Description The HL7 attribute id uses an identifier to identify the instance of a medical device entry. Implementation in XML Instance The Identifier Global data type flavour is used to carry this information in the XML element id as follows:
|
[1..1] [M] templateId (II) { Fixed="COCD_TP146054GB01#SupplyMedicalDevice" } |
Model Attribute Description
The HL7 attribute templateId provides a unique identifier for the template and the class name within that template. This is used to identify how the CDA standard has been constrained for NHS use. Implementation in XML Instance The Identifier External data type flavour is used to carry this information in the XML element templateId as follows:
|
[1..1] [M] text (ST) |
Model Attribute Description Implementation in XML Instance
|
[0..1] author |
This template class constrains the CDA author class. |
[1..1] [M] typeCode (CS { CNE: ParticipationType } ) { Fixed="AUT" } |
Model Attribute Description The HL7 attribute typeCode describes this class as an author participation. Implementation in XML Instance
|
[1..1] [M] contextControlCode (CS { CNE: ContextControl } ) { Fixed="OP" } |
Model Attribute Description The HL7 attribute contextControlCode uses a set of codes from the HL7 vocabulary ContextControl to determine whether participations associated with the parent act are conducted across to the child act (also associated with the child act). This set of codes also determine how these participations conduct. The conduction can only take place if the contextConductionInd in the actRelationships is set to "true". The value of this attribute is fixed in the HL7 model to "OP":
Implementation in XML Instance
|
[1..1] [M] contentId (II) { "NPFIT-300001#Role" } |
Model Attribute Description The HL7 (NHS localisation) attribute contentId, when valued in an instance, provides a unique forward pointing identifier for the template which constrains the classes and attributes which follow, for NHS use. The attribute is intended simply as a structural navigational aid and should not be relied upon as an indicator of semantic meaning. The contentId is populated at run time with a value from the allowed list contained in the model.
|
[1..1] [M] functionCode (CV { CNE:AuthorFunctionType } ) { Fixed="OA" } |
Model Attribute Description The HL7 attribute functionCode uses a code from the vocabulary AuthorFunctionType to describe the function of the author Implementation in XML Instance
|
[1..1] [M] templateId (II) { Fixed="COCD_TP146054GB01#author" } |
Model Attribute Description
The HL7 attribute templateId provides a unique identifier for the template and the class name within that template. This is used to identify how the CDA standard has been constrained for NHS use. Implementation in XML Instance The Identifier External data type flavour is used to carry this information in the XML element templateId as follows:
|
[1..1] [R] time (TS) |
Model Attribute Description The HL7 attribute time is used to define the time the author originally recorded the device. Implementation in XML Instance The XML attribute value of the XML element time shall be populated with the time that author recorded the information using a time stamp in the format yyyymmddhhmmss[+|-ZZzz] where:
Sections from the right of this representation may be left off when the sending system does not record to this level of accuracy. When hours are present, the time zone offset must also be present. Where no time is recorded or available then:
|
[1..1] participant (AuthorChoice) |
A link to the choice of author templates.
|
AuthorChoice |
Choice of authors for the medication item.
|
Used by: SupplyMedicalDevice | |
[1..1] : Template |